Cooling tower fill media

Plastic Cooling Tower Fill with Flexible Material and Size Options

WhatsApp QR Code WhatsApp QR
WeChat QR Code WeChat QR
Product Description

Plastic Cooling Tower Fill with Flexible Material and Size Options

Our Plastic Cooling Tower Fill is available in PVC, CPVC and PP, giving customers several material options when specifying fill for different cooling tower projects. Combined with multiple width choices and customizable length and thickness, the product can be supplied in configurations based on individual project requirements.

PVC, CPVC and PP Material Choices

Material selection is an important part of a plastic fill specification. This product is available in PVC, CPVC and PP, allowing customers to select the material according to their project requirements and preferred product configuration.

Offering multiple plastic materials also gives buyers greater flexibility when ordering replacement fill or preparing specifications for a new cooling tower project.

Multiple Width Options

The available width range includes:

  • 710mm
  • 720mm
  • 810mm
  • 820mm
  • 910mm
  • 920mm
  • 1010mm
  • 1020mm
  • 1120mm
  • 1220mm
  • 1320mm
  • 1520mm

The selection of widths provides a practical range for different plastic fill requirements, while the overall product dimensions can be further specified according to the project.

18mm Pitch and 5.5° Angle

The fill features an 18mm pitch and a 5.5° angle. These specifications define the corrugated configuration of the product and remain consistent across the available width options.

Customized Length and Thickness

While multiple widths are available, length and thickness can be customized. This makes the product suitable for orders where the required fill dimensions do not correspond to one fixed standard size.

Product Specifications

Product TypePlastic Cooling Tower Fill
Width Range710mm, 720mm, 810mm, 820mm, 910mm, 920mm, 1010mm, 1020mm, 1120mm, 1220mm, 1320mm, 1520mm
LengthCustomized
ThicknessCustomized
Pitch18mm
MaterialPVC, CPVC, PP
Angle5.5°

Plastic Fill Made to Your Specification

With three material options, multiple available widths and customizable length and thickness, this Plastic Cooling Tower Fill can be specified around different project requirements. Customers can provide their preferred material and dimensions, and the fill can be prepared according to the requested product configuration.

User Reviews
Lukas Weber
Lukas Weber
Industrial Cooling System Engineer

We purchased cooling tower fill media for an industrial cooling system renovation project. The product quality was consistent, and the customized dimensions matched our cooling tower requirements accurately. The supplier provided professional suggestions during the selection process and maintained good communication throughout the cooperation.

Nguyen Minh Hoang
Nguyen Minh Hoang
Cooling Tower Maintenance Manager

We used their PVC film fill and PP fill media for cooling tower replacement work. The products arrived well packed and were easy to install. Their technical team helped us choose suitable cooling tower fill solutions according to our operating conditions. We are satisfied with the product performance and service experience.

Omar Khalid
Omar Khalid
Mechanical Equipment Procurement Specialist

The cooling tower packing materials supplied by this manufacturer were used for our commercial building cooling system project. The corrugated fill structure showed good production accuracy and stable quality. The supplier responded quickly to our questions and provided useful support from inquiry to delivery.

Rafael Oliveira
Rafael Oliveira
Water Treatment Project Manager

We selected their cooling tower fill products for several replacement applications. The film fill and cross flow fill products met our project requirements with reliable quality and proper packaging. The team was professional, responsive, and able to provide customized solutions for different cooling tower models.

Hot Products
Multi-Width Cross-Flow Fill
1. Multi-Width Cross-Flow Fill Introduction Adaptable Coo
Double-Wave Spliced Cooling Tower Fill
1. Double-Wave Spliced Cooling Tower Fill Introduction In
750mm Width Standard Cross-flow Cooling Tower Fill
1. 750mm Width Standard Cross-flow Cooling Tower Fill Intr
Width770mm Double‑Wave Cooling Tower Fill
1. Width 770mm Double-Wave Cooling Tower Fill Introduction
FAQ
Do you offer support for cooling tower fill installation?
We can provide installation guidance for cooling tower fill media applications worldwide. Technical assistance from our engineers can also be arranged according to project needs.
What is the usual production cycle for cooling tower fill media?
Standard processing time is about 3–5 weeks after order approval, depending on specifications and customization needs. Flexible scheduling options can be discussed.
Does your cooling tower fill media meet fire resistance requirements?
Yes, standard PVC cooling tower fill media is designed with flame-retardant properties for cooling applications. Additional material options can be discussed according to specific project requirements.
What water flow rates can your cooling tower fill media support?
Our cooling tower fill media is designed for balanced water distribution and stable heat exchange performance. Customized fill structures can be developed according to different cooling tower designs and operating conditions.
Send Us a Message
Code
Need help? Chat with us!