Product Description

Plastic Cooling Tower Fill with Multiple Width and Material Options

This Plastic Cooling Tower Fill is offered in a broad selection of widths for customers looking for flexible fill specifications. Available widths range from 710mm to 1520mm, while length and thickness can be customized according to individual order requirements.

Multiple Width Options

The available widths include 710mm, 720mm, 810mm, 820mm, 910mm, 920mm, 1010mm, 1020mm, 1120mm, 1220mm, 1320mm, and 1520mm. Providing multiple width choices makes it easier to select a suitable configuration for different cooling tower fill arrangements and replacement orders.

18mm Pitch and 5.5° Angle

The fill features an 18mm pitch with a 5.5° corrugated angle. This defined geometry gives the product a consistent structural configuration across its different available widths.

PVC, CPVC and PP Materials

As a plastic cooling tower media product, it can be supplied in PVC, CPVC, and PP. Customers can choose the material according to their project specifications, purchasing requirements, or preferred fill configuration.

Customized Length and Thickness

Width selection is complemented by customized length and thickness. This allows the finished fill dimensions to be specified according to individual cooling tower projects instead of being restricted to a fixed combination of dimensions.

Product Specifications

Width Range710mm, 720mm, 810mm, 820mm, 910mm, 920mm, 1010mm, 1020mm, 1120mm, 1220mm, 1320mm, 1520mm
LengthCustomized
ThicknessCustomized
Pitch18mm
MaterialPVC, CPVC, PP
Angle5.5°

Flexible Plastic Fill for Different Cooling Tower Orders

With a wide selection of widths, three available plastic materials, and customizable length and thickness, this Cooling Tower Fill provides a flexible product configuration for different purchasing requirements. The 18mm pitch and 5.5° angle remain consistent while customers can select the dimensions and material that suit their specific order.

User Reviews
Lukas Weber
Lukas Weber
Industrial Cooling System Engineer

We purchased cooling tower fill media for an industrial cooling system renovation project. The product quality was consistent, and the customized dimensions matched our cooling tower requirements accurately. The supplier provided professional suggestions during the selection process and maintained good communication throughout the cooperation.

Nguyen Minh Hoang
Nguyen Minh Hoang
Cooling Tower Maintenance Manager

We used their PVC film fill and PP fill media for cooling tower replacement work. The products arrived well packed and were easy to install. Their technical team helped us choose suitable cooling tower fill solutions according to our operating conditions. We are satisfied with the product performance and service experience.

Omar Khalid
Omar Khalid
Mechanical Equipment Procurement Specialist

The cooling tower packing materials supplied by this manufacturer were used for our commercial building cooling system project. The corrugated fill structure showed good production accuracy and stable quality. The supplier responded quickly to our questions and provided useful support from inquiry to delivery.

Rafael Oliveira
Rafael Oliveira
Water Treatment Project Manager

We selected their cooling tower fill products for several replacement applications. The film fill and cross flow fill products met our project requirements with reliable quality and proper packaging. The team was professional, responsive, and able to provide customized solutions for different cooling tower models.

Hot Products
Multi-Width Cross-Flow Fill
1. Multi-Width Cross-Flow Fill Introduction Adaptable Coo
Double-Wave Spliced Cooling Tower Fill
1. Double-Wave Spliced Cooling Tower Fill Introduction In
750mm Width Standard Cross-flow Cooling Tower Fill
1. 750mm Width Standard Cross-flow Cooling Tower Fill Intr
Width770mm Double‑Wave Cooling Tower Fill
1. Width 770mm Double-Wave Cooling Tower Fill Introduction
FAQ
Do you offer support for cooling tower fill installation?
We can provide installation guidance for cooling tower fill media applications worldwide. Technical assistance from our engineers can also be arranged according to project needs.
What is the usual production cycle for cooling tower fill media?
Standard processing time is about 3–5 weeks after order approval, depending on specifications and customization needs. Flexible scheduling options can be discussed.
Does your cooling tower fill media meet fire resistance requirements?
Yes, standard PVC cooling tower fill media is designed with flame-retardant properties for cooling applications. Additional material options can be discussed according to specific project requirements.
What water flow rates can your cooling tower fill media support?
Our cooling tower fill media is designed for balanced water distribution and stable heat exchange performance. Customized fill structures can be developed according to different cooling tower designs and operating conditions.